Drager Rohrchen - Ammonia 5a
Drager Rohrchen - Ammonia 5a

Drager Rohrchen - Ammonia 5a

Price 7000 INR/ Piece

MOQ : 1 Piece

Drager Rohrchen - Ammonia 5a Specification

  • Accuracy
  • 10 to 15%
  • Sensor
  • Colorimetric chemical reagent
  • Operating Temperature
  • 0C to 40C
  • Number of Specimens
  • 10 tubes per box
  • Gas Pressure
  • Atmospheric
  • Test Material
  • Ammonia (NH3)
  • Humidity
  • 10% to 90% RH non-condensing
  • Temperature
  • 0C to 40C
  • Specimen Size
  • Tube: 7 mm diameter, 110 mm length
  • Response Time
  • 1 to 5 minutes
  • Test Range
  • 5 to 70 ppm
  • Display
  • Visual Color Change
  • Type
  • Gas Detection Tube (Colorimetric)
  • Use
  • Ammonia Gas Detection
  • Test Medium
  • Air/Ambient Gases
  • Operating Voltage
  • Not Required (Manual Operation)
  • Shell Material
  • Glass
  • Net Weight
  • Approx. 15 g (per pack)
  • Operating Mode
  • Manual, with Drager Accuro Pump
  • Measuring Principle
  • Colorimetric chemical reaction
  • Compliance
  • CE Certified
  • Application
  • Industrial hygiene, air quality monitoring, leak detection
  • Shelf Life
  • 2 years from date of manufacture
  • Model Number
  • Ammonia 5a
  • Storage Conditions
  • Keep in a cool and dry place
  • Compatible Device
  • Drager Accuro Pump and Aerotest systems
 

Drager Rohrchen - Ammonia 5a Trade Information

  • Minimum Order Quantity
  • 1 Piece
  • Payment Terms
  • Cash in Advance (CID)
  • Supply Ability
  • 100 Pieces Per Month
  • Delivery Time
  • 7 Days
  • Main Domestic Market
  • All India
 

About Drager Rohrchen - Ammonia 5a



Seize our Advance Purchase Offer on the Drager Rohrchen - Ammonia 5a and enjoy a meritorious discount on your next order. This polished gas detection tube, Model: Ammonia 5a, is engineered for valiant performance in industrial hygiene and air quality monitoring. Employing a colorimetric chemical reaction for ammonia detection between 5-70 ppm, it operates manually with Drager Accuro Pump or Aerotest systems-no external voltage needed. CE Certified and housed in a robust glass shell, it assures accuracy (10-15%) and convenience for leak detection. Each box contains 10 tubes, ideal for atmospheric pressure usage.

Comprehensive Applications and Meritorious Features

The Drager Rohrchen - Ammonia 5a is purpose-built for industrial hygiene, leak detection, and ambient air quality surveillance. Designed to deliver visual color change within 1-5 minutes, it excels in detecting ammonia gas across 5-70 ppm. The polished design is compatible with the Drager Accuro Pump and Aerotest systems, facilitating a valiant and reliable process every time. Suitable for air and ambient gases, it incorporates a colorimetric chemical reagent, supporting thorough workplace safety audits.


Premium Sample Policy and Packaging Details

Drager Rohrchen - Ammonia 5a reflects premium market value with its robust packaging-each box safely contains 10 high-precision tubes. Dedicated to preserving product integrity, the tubes are dispatched in secure, climate-appropriate packaging from our FOB port in India, ensuring timely delivery. Adhering to our esteemed sample policy, clients are assured a smooth ordering experience and premium support, underlining our commitment to your satisfaction in every transaction.


FAQ's of Drager Rohrchen - Ammonia 5a:


Q: How does the Drager Rohrchen - Ammonia 5a detect ammonia gas?

A: The Drager Rohrchen - Ammonia 5a utilizes a colorimetric chemical reaction to detect ammonia gas. When exposed to ammonia, the reagent in the glass tube changes color, providing a clear, visual indication of concentration within 1 to 5 minutes.

Q: What is the optimal way to use this gas detection tube?

A: To use the Drager Rohrchen - Ammonia 5a, insert the tube into the compatible Drager Accuro Pump or Aerotest system and draw a sample of ambient air. Observe the resulting color change to determine the ammonia concentration, with results provided accurately within minutes.

Q: Where can Drager Rohrchen - Ammonia 5a be used effectively?

A: This detection tube is ideal for industrial hygiene, workplace safety assessments, air quality monitoring, and leak detection in various atmospheric environments, particularly where ammonia presence or exposure risk is a concern.

Q: When should I replace the detection tubes?

A: The detection tubes should be used within the 2-year shelf life from the date of manufacture. It is advisable to store them in cool, dry conditions and replace any tubes that are past their expiry date for optimum accuracy.

Q: What are the benefits of purchasing under the current Advance Purchase Offer?

A: By choosing our Advance Purchase Offer, customers benefit from exclusive discounts while securing genuine, CE Certified Drager detection tubes. This cost-effective approach ensures readiness for ongoing workplace safety and monitoring needs.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Gas Detector Equipment Category

Drager Aerotest Simultan HP Breathing Air Quality Test Kit

Drager Aerotest Simultan HP Breathing Air Quality Test Kit

Minimum Order Quantity : 1 Piece

Type : Other, HP (High Pressure) Breathing Air Quality Test Kit

Use : Testing and monitoring breathing air quality according to EN 12021

Response Time : 110 minutes depending on parameter

Shell Material : Robust plastic carrying case

Unitor Unirx-1A Refrigerant Leak Detector

Unitor Unirx-1A Refrigerant Leak Detector

Price 5000 INR / Piece

Minimum Order Quantity : 1 Piece

Type : Other, Portable leak detector

Use : Refrigerant leak detection

Response Time : Instant

Shell Material : Fiber

HC Detector

HC Detector

Price 18000 INR / Pole

Minimum Order Quantity : 1 Piece

Type : Other, HC Detector

Use : Industrial, Ship

Response Time : <15 seconds

Drager Accuro Gas Detection Pump

Drager Accuro Gas Detection Pump

Price 10000 INR / Piece

Minimum Order Quantity : 1 Piece

Type : Other, Manual gas detection pump

Use : Industrial

Shell Material : Fibre